Difference between revisions of "Active Directory/Documentation/Add Driver To RIS"

From WolfTech
Jump to navigation Jump to search
m
 
(8 intermediate revisions by one other user not shown)
Line 3: Line 3:
 
# On the RIS server, copy the Windows 2000 .inf and .sys files for the network adapter to the RemoteInstall\Setup\English\Images\<IMAGE>\i386 folder. This allows Setup to use the driver during the text-mode portion of the installation.
 
# On the RIS server, copy the Windows 2000 .inf and .sys files for the network adapter to the RemoteInstall\Setup\English\Images\<IMAGE>\i386 folder. This allows Setup to use the driver during the text-mode portion of the installation.
 
# Copy the Windows XP driver files to $oem$\$1\Drivers\Nic.
 
# Copy the Windows XP driver files to $oem$\$1\Drivers\Nic.
# Stop and then restart the Remote Installation service (BINLSVC) on the RIS server. To do this, type the following commands at the command prompt and press ENTER after each command:
+
# Stop and then restart the Remote Installation service (BINLSVC) on the RIS server. To do this, type the following commands at the command prompt and press ENTER after each command:<BR>
net Stop binlsvc
+
<pre>net Stop binlsvc</pre>
net Start binlsvc
+
<pre>net Start binlsvc</pre>
 
Stopping and restarting the Remote Installation service is necessary because the Boot Information Negotiation Layer (BINL) needs to read all the new network adapter-related .inf files and create .pnf files in the image. This is a time-consuming task and is performed only when the Remote Installation service starts.
 
Stopping and restarting the Remote Installation service is necessary because the Boot Information Negotiation Layer (BINL) needs to read all the new network adapter-related .inf files and create .pnf files in the image. This is a time-consuming task and is performed only when the Remote Installation service starts.
 +
 +
'''Note from Brian''': Newer WDS servers have a different service to stop and restart, ''Single Instance Storage Groveler''
 +
<pre>net Stop groveler</pre>
 +
<pre>net Start groveler</pre>
  
 
=SATA Driver=
 
=SATA Driver=
 +
See [http://h10025.www1.hp.com/ewfrf/wc/document?lc=en&cc=be&dlc=en&product=3204907&lang=en&docname=c00758841#N823 here]
  
 
=Other Drivers=
 
=Other Drivers=
 +
# Download the Windows XP drivers for the device.
 +
# Copy the Windows XP driver files to $oem$\$1\Drivers\<CATEGORY>, where <CATEGORY> is the folder that best describes the device.

Latest revision as of 09:39, 25 July 2007

NIC Driver

  1. Download both the Windows 2000 and Windows XP drivers for the NIC.
  2. On the RIS server, copy the Windows 2000 .inf and .sys files for the network adapter to the RemoteInstall\Setup\English\Images\<IMAGE>\i386 folder. This allows Setup to use the driver during the text-mode portion of the installation.
  3. Copy the Windows XP driver files to $oem$\$1\Drivers\Nic.
  4. Stop and then restart the Remote Installation service (BINLSVC) on the RIS server. To do this, type the following commands at the command prompt and press ENTER after each command:
net Stop binlsvc
net Start binlsvc

Stopping and restarting the Remote Installation service is necessary because the Boot Information Negotiation Layer (BINL) needs to read all the new network adapter-related .inf files and create .pnf files in the image. This is a time-consuming task and is performed only when the Remote Installation service starts.

Note from Brian: Newer WDS servers have a different service to stop and restart, Single Instance Storage Groveler

net Stop groveler
net Start groveler

SATA Driver

See here

Other Drivers

  1. Download the Windows XP drivers for the device.
  2. Copy the Windows XP driver files to $oem$\$1\Drivers\<CATEGORY>, where <CATEGORY> is the folder that best describes the device.