Difference between revisions of "Active Directory/Documentation/Add Driver To RIS"
Jump to navigation
Jump to search
Line 3: | Line 3: | ||
# On the RIS server, copy the Windows 2000 .inf and .sys files for the network adapter to the RemoteInstall\Setup\English\Images\<IMAGE>\i386 folder. This allows Setup to use the driver during the text-mode portion of the installation. | # On the RIS server, copy the Windows 2000 .inf and .sys files for the network adapter to the RemoteInstall\Setup\English\Images\<IMAGE>\i386 folder. This allows Setup to use the driver during the text-mode portion of the installation. | ||
# Copy the Windows XP driver files to $oem$\$1\Drivers\Nic. | # Copy the Windows XP driver files to $oem$\$1\Drivers\Nic. | ||
− | # Stop and then restart the Remote Installation service (BINLSVC) on the RIS server. To do this, type the following commands at the command prompt and press ENTER after each command:<BR><pre>net Stop binlsvc</pre><pre>net Start binlsvc</pre | + | # Stop and then restart the Remote Installation service (BINLSVC) on the RIS server. To do this, type the following commands at the command prompt and press ENTER after each command:<BR><pre>net Stop binlsvc</pre><pre>net Start binlsvc</pre>Stopping and restarting the Remote Installation service is necessary because the Boot Information Negotiation Layer (BINL) needs to read all the new network adapter-related .inf files and create .pnf files in the image. This is a time-consuming task and is performed only when the Remote Installation service starts. |
=SATA Driver= | =SATA Driver= | ||
=Other Drivers= | =Other Drivers= |
Revision as of 17:14, 5 July 2007
NIC Driver
- Download both the Windows 2000 and Windows XP drivers for the NIC.
- On the RIS server, copy the Windows 2000 .inf and .sys files for the network adapter to the RemoteInstall\Setup\English\Images\<IMAGE>\i386 folder. This allows Setup to use the driver during the text-mode portion of the installation.
- Copy the Windows XP driver files to $oem$\$1\Drivers\Nic.
- Stop and then restart the Remote Installation service (BINLSVC) on the RIS server. To do this, type the following commands at the command prompt and press ENTER after each command:
net Stop binlsvc
net Start binlsvc
Stopping and restarting the Remote Installation service is necessary because the Boot Information Negotiation Layer (BINL) needs to read all the new network adapter-related .inf files and create .pnf files in the image. This is a time-consuming task and is performed only when the Remote Installation service starts.